As a rule of thumb for rooms with a standard ceiling height of about 10 ft: up to about 120 sq ft needs around 1 ton, 120–180 sq ft about 1.5 tons, and 180–250 sq ft about 2 tons. Go one step up for top-floor or west-facing rooms, rooms with large glass areas, kitchens or rooms with many people. Treat this as a starting point; the AC brand or installer can calculate the load for your room.
In this guide
AC size matters for interiors because the indoor unit, piping and drain have to be planned before ceilings, panels and wardrobes go in. This page gives a simple sizing guide and the planning points. Typical room sizes are in our standard room sizes guide.
AC tonnage chart by room size
| Room size (sq ft) | Example room | Typical tonnage |
|---|---|---|
| Up to 100 | 10 × 10 ft bedroom | 1 ton |
| 100–120 | 10 × 12 ft bedroom | 1 ton (1.5 ton if hot) |
| 120–150 | 12 × 12 ft bedroom | 1.5 ton |
| 150–180 | 12 × 14 ft master bedroom | 1.5 ton |
| 180–250 | Living room 14 × 16 ft | 2 ton |
| Above 250 | Large living-dining | 2 ton or two units |
Rule of thumb for a ceiling height of about 10 ft. For our own room size references, see bedroom sizes and living room sizes.

What changes the size you need
| Factor | Effect |
|---|---|
| Top floor or roof exposure | Go up about 0.5 ton |
| West- or south-west-facing windows | Go up if the room gets strong afternoon sun |
| Large glass doors or windows | More heat gain |
| High ceilings (double height) | Calculate by volume, not floor area |
| Number of people and appliances | More heat; living rooms and home offices need more |
| Good insulation and curtains | Can stay at the lower size |
An oversized AC cools fast but switches on and off often and removes less humidity. Undersized units run constantly. Ask the installer to size by heat load if your room is unusual.
Planning AC points during interiors
- Position: on an outer wall, above the window or bed head, not blowing directly on the bed.
- Height: indoor unit top typically about 7–8 ft from the floor, with clearance below the ceiling.
- Piping and drain: concealed copper piping and drain pipe laid before plaster, panelling or false ceilings.
- Power: a dedicated socket or isolator for each AC.
- Outdoor unit: on the balcony or ledge with service access and airflow.

Mark AC points in your electrical plan before interiors.
Interior details around the AC
- Keep the AC clear of wardrobe lofts and curtain pelmets so air flows freely.
- If the AC sits on a panelled wall, leave a removable panel for pipe access.
- Do not box the indoor unit inside a false ceiling unless it is a ceiling-type or ducted unit.
- Use blackout or thermal curtains on sunny windows (see curtains vs blinds).
Common mistakes when choosing an AC
Picking the right tonnage is only part of the job. These mistakes affect comfort and running cost just as much.
- Ignoring sun and glass. A west-facing room with large windows heats up more than a shaded room of the same size. Discuss this with your AC dealer rather than going by area alone.
- Placing the indoor unit above the bed. Cold air blowing directly onto people is uncomfortable. Place the unit so the air flows across the room.
- Long or poorly planned piping. Long copper runs and many bends can affect performance. Keep the outdoor unit as close as practical and plan the route before the false ceiling and panelling go in.
- No drain plan. Decide where the condensate water will go so it does not drip on a balcony or neighbour’s window.
- Blocking the airflow. Curtain pelmets, tall wardrobes or ceiling details that sit too close to the unit can restrict air.
Before the interiors start
- Fix AC positions on the drawing for every room.
- Run concealed copper piping, drain and power before plaster or panelling.
- Leave access for service.
Frequently asked questions
What ton AC do I need for a 120 sq ft room?
About 1 ton for a standard room, or 1.5 ton if the room is on the top floor or gets strong sun.
Is 1.5 ton AC enough for 150 sq ft?
Usually yes, for a room with a standard ceiling height and normal sun exposure.
What ton AC is needed for a 200 sq ft living room?
Around 2 tons, more if the room has large glass areas or is on the top floor.
Does ceiling height affect AC size?
Yes. Higher or double-height ceilings increase the volume to cool, so size by volume or heat load.
When should AC piping be done?
Before plaster, false ceilings, panelling and wardrobes, so pipes and drains can be concealed.
Is a bigger AC always better?
No. An oversized AC cycles too often and controls humidity poorly; size it to the room.